On expansive clay, roof water dumped next to the slab can swell the soil under one side of the house. The residential code Texas cities use says roof drainage on such soils must reach the ground at least 5 feet from the foundation, or go into an approved drainage system.
At least 5 feet on expansive soil. IRC Section R801.3 (2021) reads: 'In areas where expansive soils or collapsible soils are known to exist, all dwellings shall have a controlled method of water disposal from roofs that will collect and discharge roof drainage to the ground surface not less than 5 feet (1524 mm) from foundation walls or to an approved drainage system.'
HUD's general guidance is lower. Downspout water should go at least 2 feet from the house, and further on expansive clays, according to HUD's Moisture-Resistant Homes guide (2006). On Texas clay, use the 5-foot code figure as the floor.
Yes, in Texas cities. Texas Local Government Code Section 214.212 adopts the International Residential Code, as it existed on May 1, 2012, as the municipal residential building code. Cities may adopt local amendments after a public hearing and by ordinance.
The 2012 IRC contains the same roof drainage rule, with the same 5-foot distance. Check which code edition and amendments your city has adopted.
Clay with a high plasticity index swells when wet and shrinks when dry, and that movement lifts and drops a slab. The Foundation Performance Association (FPA), a Houston group of engineers, says soil with an effective PI of 35 or more has a large shrink and swell potential.
Gutters gather rain from a whole roof face into a few points. If that water is not controlled, yard drainage and the foundation can end up worse off than with no gutters at all, the FPA warns.
Not on expansive clay. A splash block carries water about 18 inches or more from the foundation, according to the FPA, and discharge onto a splash block breaks the code's 5-foot rule for expansive soil.
Splash blocks still help on firm, sloped ground or under an extension. Always point the discharge away from the house.
You can extend the downspout above ground or pipe it underground. The FPA lists the choices for the base of a downspout.
On high-PI clay, buried pipe is the recommended route. For soil with an effective PI of 35 or more, the FPA recommends full guttering with underground drainage in non-perforated pipe, carrying water away from the soil that supports the foundation.
Build it to be cleaned. The FPA says a buried system needs a screen at the gutter outlet so debris stays at the roofline, and pipe joints near foundations must be connected and sealed. Rigid PVC can be rodded clean, while flexible corrugated pipe cannot be rodded and is harder to keep on slope.
Underground gutter drainage costs $2,200 to $3,300 on average in 2026, according to Angi. Permit fees can add $300 to $1,500, Angi notes.
It should come out at a point lower than the house where water can flow away. Common outlets are the street curb or a pop-up emitter in the yard.
A curb outlet usually uses 4-inch Schedule 40 PVC, and a curb cut may need city approval, according to the FPA. Where curb cuts are not allowed, a pop-up emitter on the yard side is an option. Pop-ups can clog and grow algae, and they leave water standing in the pipe behind them, the FPA notes.
Dry wells are rarely practical on clay, which absorbs water slowly, according to the FPA.
No. A French drain collects water from inside the soil through perforated pipe. It is not meant to carry surface or roof water, according to the FPA.
Never tie downspouts into a French drain's collection pipe. Doing so pushes roof water into the soil instead of removing it, the FPA warns. Keep roof water in solid pipe, and keep the yard graded so it falls at least 6 inches in the first 10 feet from the house, as IRC Section R401.3 requires.
Local prices and the local record: Houston, San Antonio, Dallas, Fort Worth, Austin, El Paso, Arlington, Corpus Christi. Every Texas county.
At least 5 feet from the foundation on expansive or collapsible soil, under IRC Section R801.3, unless it drains into an approved drainage system.
Not on expansive clay. A splash block moves water about 18 inches, which falls short of the 5-foot code rule, according to the Foundation Performance Association.
On clay with an effective PI of 35 or more, the Foundation Performance Association recommends underground drainage in non-perforated pipe.
No. Feeding roof water into French drain collection pipe adds water to the soil, according to the Foundation Performance Association. Use solid pipe for roof water.
Between $2,200 and $3,300 on average in 2026, according to Angi, plus possible permit fees of $300 to $1,500.
The grade should fall at least 6 inches within the first 10 feet from the foundation, under IRC Section R401.3.
Sources: ICC: 2021 International Residential Code, Chapter 8 (R801.3 Roof drainage) · ICC: 2021 International Residential Code, Chapter 4 (R401.3 Drainage) · Texas Local Government Code Section 214.212 · Foundation Performance Association: FPA-SC-17-0 Drainage Guidelines (2012) · HUD: Moisture-Resistant Homes (2006), Section 2.2.5 · Angi: Cost to install underground gutter drainage (2026)