R-454B is a lower-impact refrigerant that replaced R-410A in most new home AC and heat pump systems from 2025. You can still repair an R-410A system. Installers can still fit R-410A equipment built before 2025 until stock runs out, under a May 2026 EPA rule.
R-454B is a refrigerant blend sold under names such as Opteon XL41. It is acceptable, with use conditions, for new residential and light commercial AC and heat pumps, according to EPA.
R-454B has a global warming potential of 470, according to EPA. R-410A, the refrigerant in most Texas systems installed since the 2010s, is rated 2,090. R-32 is another common replacement at 675.
R-454B carries an A2L safety class. That means low toxicity and lower flammability. It is allowed only with use conditions, under EPA rules, so installers must follow the equipment maker's A2L instructions.
EPA's rules cap the global warming potential (GWP) of residential and light commercial AC and heat pump systems at 700, under its Technology Transitions rule. HFC production and use must be phased down by 85% by 2036, under the AIM Act.
For products such as packaged units and window units, the limit applies to manufacture and import from January 1, 2025. For new split systems, it applies to installation from January 1, 2025.
In 2026, the deadline for installing pre-2025 R-410A equipment was removed by a final EPA rule published in May 2026. EPA had first allowed R-410A equipment made before 2025 to be installed until January 1, 2026. Pre-2025 R-410A inventory can now be installed until supply runs out.
| Refrigerant | GWP | Safety class | Status for new home systems |
|---|---|---|---|
| R-410A | 2,090 | A1 | Over the 700 limit. Pre-2025 stock may still be installed |
| R-32 | 675 | A2L | Acceptable with use conditions |
| R-454B | 470 | A2L | Acceptable with use conditions |
Common home AC refrigerants (EPA SNAP listing)
Ask which refrigerant the system uses, and the other questions below. Most new systems quoted in Texas now use R-454B or R-32. Some contractors may still offer leftover R-410A equipment, which is legal if all of it was made or imported before 2025.
An R-410A unit may be cheaper up front. The trade-off is future service. R-410A supply is shrinking under the HFC phase-down, so recharges may cost more over the system's life. We could not find a reliable published price trend, so ask your contractor for a written quote on refrigerant costs.
You do not need to replace a working R-410A system. The installation restrictions do not apply to components used to repair existing systems, according to EPA.
Technicians can still recharge R-410A and replace parts such as compressors and coils. If the outdoor unit and indoor coil both need replacing, that counts as a new system, so price a full R-454B or R-32 swap at the same time.
No. Each refrigerant needs equipment designed and listed for it. Do not let anyone top up an R-410A system with R-454B or pair a new R-454B outdoor unit with an old R-410A coil. Ask the contractor to confirm in writing that the indoor and outdoor units are a matched, listed set.
Local prices and the local record: Harris County, Dallas County, Tarrant County, Bexar County, Travis County, Collin County, Denton County, Fort Bend County. Every Texas county.
No, not for repairs. New R-410A systems are restricted, but systems made or imported before January 1, 2025 can be installed until stock runs out, under EPA rules since May 2026.
No. You can keep repairing and recharging it. Repair parts are exempt from the installation rules.
Yes, when installed to the rules. It is classed A2L, meaning low toxicity and mildly flammable. It is allowed only with use conditions, under EPA rules, and equipment makers build these into the system.
No. R-454B is listed for new equipment only, not retrofit, by EPA. Do not mix refrigerants.
Supply is shrinking under the HFC phase-down. We could not verify a published price figure, so get refrigerant costs in writing.
Sources: US EPA, Technology Transitions HFC Restrictions by Sector · US EPA, Regulatory Actions for Technology Transitions · US EPA, Technology Transitions Reconsideration Rule technical fact sheet (May 2026) · US EPA SNAP, Substitutes in Residential and Light Commercial Air Conditioning and Heat Pumps · US EPA, HFC Allowance Allocation and Reporting